Specifications:
- The working voltage: 3.3V-5V
- The output format: DO digital switching outputs (0 and 1) and AO analog voltage output
- Comparator: wide voltage LM393
- Length: 4.5cm / 1.77in
Wiring instructions:
- VCC: 3.3-5V power supply “+”
- GND: power supply “-“
- DO: TTL switch signal output.
- AO: analog signal output (voltage signal)
Instructions for use:
- The flame sensor is most sensitive to flame, for ordinary light, it is also responsive , generally used as a flame alarm purposes.
- The output interface can be directly connected to the micro-controller IO port.
- The sensor must be kept at a distance from the flame to avoid damage to the sensor. lighter flame test distance of 80cm, for the greater flame, the farther the distance test.
- Analog output and the AD conversion process, can achieve higher accuracy.
- When the sensor detects a flame, sunlight, or infrared light, if achieve potentiometer setting threshold, the green indicator light will ON, the DO output low level (0-0.1 – V), the green light is OFF, the DO output about 3 V high voltage level